• <th></th>

    <span><legend id="DG1nRs"></legend></span>

                    Three box-type Thermal shock Test Chamber BND-HLR3

                    Product Description:Name:Three box-type Thermal shock Test ChamberType:BND-HLR3Purpose:It is necessary test equipment for the aerospace, automotive, home appliances, research and other fields, used for examination and identification of parameters, performance and the use of adaptive of electrical, electronics, automotive electronics, materials and other products, after making high and low temperature impact test. Applied to schools, factories, military, research, and other organizations
                    Description

                    Product Description:

                    Name:Three box-type Thermal shock Test Chamber

                    Type:BND-HLR3


                    Purpose:

                    It is necessary test equipment for the aerospace, automotive, home appliances, research and other fields, used for examination and identification of parameters, performance and the use of adaptive of electrical, electronics, automotive electronics, materials and other products, after making high and low temperature impact test. Applied to schools, factories, military, research, and other organizations


                    Product Spec.and Technical parameter table

                    model

                    BND-HLR3-80

                    BND-HLR3-100

                    BND-HLR3-150

                    performance

                    Preheat room

                    Upper limit preheat temperature

                    200ºC

                    Heating time

                    ﹢20~﹢200ºC≈20min

                    Precool room

                    Lower limit precool temperature

                    ﹣75ºC

                    Cooling time

                    ﹢20~﹣70ºC≈80min

                    Workroom

                    Temperature shock range

                    (-55ºC~-10)~(50~﹢150ºC)

                    Temperature fluctuation

                    ≤±0.5ºC

                    Temperature deviation

                    ≤±2ºC

                    Temperature revert time

                    ≤5min

                    Temperature revert
                           conditions

                    CJ602S3Ⅰ

                    Condition 1

                    sample load: 10kg with  plastic package IC;sample exposed: 30min in ﹢125ºC,30min in ﹣40ºC

                    Condition 2

                    sample load: 10kg with  plastic package IC;sampl exposed :30min in ﹢150ºC,5min in ambient temp,30min in ﹣55ºC

                    CJ602S3Ⅱ

                    Condition 1

                    sample load: 20kg with  plastic package IC;sample exposed: 30min in ﹢125ºC,30min in ﹣40ºC

                    Condition 2

                    sample load: 20kg with  plastic package IC;sampl exposed :30min in ﹢150ºC,5min in ambient temp,30min in ﹣55ºC

                    Condition 3

                    sample load: 7.5kg with  plastic package IC;sample exposed: 30min in ﹢150ºC,30min in ﹣55ºC

                    CJ603S3Ⅰ

                    Condition 1

                    sample load: 10kg with  plastic package IC;sample exposed: 30min in ﹢125ºC,30min in ﹣40ºC

                    Condition 2

                    sample load: 10kg with  plastic package IC;sampl exposed :30min in ﹢150ºC,5min in ambient temp,30min in ﹣55ºC

                    CJ603S3Ⅱ

                    Condition 1

                    sample load: 20kg with  plastic package IC;sample exposed: 30min in ﹢125ºC,30min in ﹣40ºC

                    Condition 2

                    sample load: 20kg with  plastic package IC;sampl exposed :30min in ﹢150ºC,5min in ambient temp,30min in ﹣55ºC

                    Condition 3

                    sample load: 10kg with  plastic package IC;sample exposed: 30min in ﹢150ºC,30min in ﹣55ºC

                    CJ605S3Ⅰ

                    Condition 1

                    sample load: 10kg with  plastic package IC;sample exposed: 30min in ﹢125ºC,30min in ﹣40ºC

                    Condition 2

                    sample load: 10kg with  plastic package IC;sampl exposed :30min in ﹢150ºC,5min in ambient temp,30min in ﹣55ºC

                    CJ605S3Ⅱ

                    Condition 1

                    sample load: 20kg with  plastic package IC;sample exposed: 30min in ﹢125ºC,30min in ﹣40ºC

                    Condition 2

                    sample load: 20kg with  plastic package IC;sampl exposed :30min in ﹢150ºC,5min in ambient temp,30min in ﹣55ºC

                    Condition 3

                    sample load: 10kg with  plastic package IC;sampl exposed :30min in ﹢150ºC,30min in ﹣55ºC

                    construction

                    shell

                    cooling steel plate,surface spray

                    inner

                    steel plate

                    refrigeration

                    insulate

                    Rigid Polyurethane Foam+extra-fine glass-wool

                    mode

                    cascade refrigerating compressor

                    compressor

                    import compressor

                    Cable port(mm)

                    one on left side Φ50

                    Controller

                    color LCD touchscreen display

                    recording equipment

                    temperature recorder(optional)

                    communication Interface

                    RS485 interface,RS232 interface

                    Workroom dimensions(mm)

                    D

                    400

                    400

                    500

                    W

                    500

                    500

                    600

                    H

                    400

                    500

                    500

                    Exterior dimensions(mm)

                    D

                    2500

                    2700

                    2900

                    W

                    1000

                    1000

                    1130

                    H

                    1950

                    2000

                    2100

                    Installed power(KW)

                    35

                    48

                    50

                    46

                    56

                    56

                    Power Supply

                    AC380V 50Hz Three-phase four-wire + protective earth wire

                    Standard Configuration

                    A copy of the instruction and test report for the product, A certificate and quality assurance.2 Shelf and 4 shelves .

                    Standards Applied

                    GJB150.5

                    LWfAS