• <th></th>

    <span><legend id="DG1nRs"></legend></span>

                    ORP10 ORP Transmitter Oxidation Reduction Potential Sensor

                    Oxidation Reduction Potential (ORP) is a measurement of sanitizer effectiveness in water. ORP is an electronic measurement in millivolts (mV) of the ability of a chemical substance to oxidize or reduce another chemical substance. The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial, water processing, sewerage system, irrigation, smart agriculture etc.
                    Description

                    Product Description:

                    Name:ORP10 ORP Transmitter Oxidation Reduction Potential Sensor

                    Type:ORP10

                    Oxidation Reduction Potential (ORP) is a measurement of sanitizer effectiveness in water. ORP is an electronic measurement in millivolts (mV) of the ability of a chemical substance to oxidize or reduce another chemical substance. The output signal can be RS485, Analog Voltage or Analog Current. The sensor is applicable for industrial, water processing, sewerage system, irrigation, smart agriculture etc.

                    ■ ORP measurement

                    ■ Output Interface with RS485, Voltage, Current

                    ■ High accuracy with excellent stability

                    ■ Reverse power protection and Built-in TVS/ESD protection


                    Specifications


                    Output Interface

                    Analog Voltage 0-2V        

                    (Output resistance ~0ohm)

                    Analog Current 4-20mA        

                    (Load Resistor<500ohm)

                    RS485        

                    Modbus-RTU

                    Power Supply

                    3.9-30V/DC

                    12-30V/DC

                    3.9-30V/DC

                    Power Consumption

                    10mA@24V DC

                    30mA@24V DC        

                    (with 20mA output signal)

                    10mA@24V DC

                    ORP Measurement

                    Range:+/-2000mV,Resolution:1mV,Accuracy:±2%

                    IP Ratings

                    Electrode:IP68        

                    Transmitter:IP65

                    Operating Temperature

                    -40~85℃

                    Installation

                    Electrode:3/4″NPT screw threads        

                    Transmitter:Mounting hole

                    Cable Length

                    Power and Signal Cable:2 meters or Customize        

                    Electrode Cable:5 meters

                    Dimension

                    Electrode:3/4″NPT screw threads        

                    Transmitter:128*70*42mm



                    Parameters

                    Code

                    Comments

                    Code 1:        

                    Product Series

                    ORP10

                    ORP10 transmitter

                    Code 2:        

                    Power Supply

                    A        

                    B

                    3.9-30V DC        

                    3.3-16V

                    Code 3:        

                    ORP Range

                    A        

                    B

                    C

                    +/-2000mV        

                    +/-1000mV

                    Customize

                    Code 4:        

                    Output Interface

                    A        

                    B

                    C

                    D

                    E

                    F

                    G

                    Analog Voltage 0-2V        

                    Analog Current 4-20mA

                    RS485,Modbus-RTU

                    RS485,Modbus-RTU & Analog Voltage 0-2V

                    RS485,Modbus-RTU & Analog Current 4-20mA

                    SDI-12

                    Customize

                    Code 5:        

                    Cable Length

                    002        

                    XXX

                    Electrode Cable:5 meters , Power and Signal Cable:2 meters        

                    Electrode Cable:5 meters , Power and Signal Cable:xxx meters

                    Ordering Code Example:

                    ORP10 transmitter Power Supply 3.9-30V DC, ORP Range +/-2000mV, Output Interface RS485, Modbus-RTU, Power and Signal Cable Length 5 meters. Ordering Code is : ORP10 – A A C 005

                    OCIgI
                  1. <th></th>

                    <span><legend id="DG1nRs"></legend></span>