• <th></th>

    <span><legend id="DG1nRs"></legend></span>

                    UL 94 Horizontal and vertical flame test apparatus BND-SPR

                    The horizontal and vertical burning test mainly refers to UL 94-2006, IEC 60695-11-4, IEC 60695-11-3, GB/T5169-2008 series and other standards, using Bunsen burner of specified size and specific gas source (Methane or propane), according to a certain flame height and a certain flame angle, the test sample in a horizontal or vertical state is regularly burned several times, and its flammability is evaluated by the duration and burning length of the test sample‘s ignition and burning. Sex and fire hazard.
                    Description

                    Product Description:

                    Name:UL 94 Horizontal and vertical flame test apparatus

                    Type:BND-SPR


                    The Basic introduction of the flame tester:

                    1. The horizontal and vertical burning test mainly refers to UL 94-2006, IEC 60695-11-4, IEC 60695-11-3, GB/T5169-2008 series and other standards, using Bunsen burner of specified size and specific gas source (Methane or propane), according to a certain flame height and a certain flame angle, the test sample in a horizontal or vertical state is regularly burned several times, and its flammability is evaluated by the duration and burning length of the test sample's ignition and burning. Sex and fire hazard.

                    2. HVR-4 horizontal and vertical combustion tester is mainly used for grading assessment of the flammability of V-0, V-1, V-2, HB, and 5V materials. It is suitable for the research, production and quality inspection departments of electrical and electronic products and their components such as lighting equipment, low-voltage electrical appliances, household appliances, machine tool electrical appliances, motors, power tools, electronic instruments, electrical meters, electrical connectors and accessories. Used in insulation materials, engineering plastics or other solid combustible materials industries.


                    Technical Parameter of flame test:

                    Model

                    BND-SPR   Horizontal vertical flame tester

                    Kinds

                     500W(5V class )

                     50W(HB/V class)

                    Test Flame

                    500W(burning test for V-0,V-1,V-2  classification)

                    50W(burning test for V-0,V-1,V-2 classification)

                    Burner Tube

                    Internal diameter: Φ 9.5mm±0.3mm

                    Internal diameter: Φ 9.5mm±0.3mm, 

                    Burning Angle

                    0°,20°,45°

                    0°,20°,45°

                    Thermocouple

                    Type K (Ni/Cr - Ni/Al)

                    Type K (Ni/Cr - Ni/Al)

                    Thermocouple Size 

                    0.5 mm

                    0.5 mm

                    Standard Copper Block 

                    9mm±0.01mm,

                    weight:10g±0.05g before drilling.  

                    5.5mm±0.01mm,

                    weight:76g±0.01g before drilling.

                    Time for Temperature to Increase

                    From 100°C±5°C to 700°C±3°C; 54s±2s (preset)

                    From 100°C±5°C to 700°C±3°C;

                    44s±2s (preset)

                    Gas Flow

                    965±32ml/min

                    105±10ml/min

                    Gas Supply

                    methane,min.98% purity

                    methane,min.98% purity

                    water-column 

                    125m±5mm

                    ‹10mm

                    Test  Time

                    54±2s

                    44±2s

                    Flame Height Indicator

                    40±1mm

                    20±1mm

                    Volume Of Chamber

                    >0.5m³, black interior

                    >0.5m³, black interior

                    Conform to standard

                    UL94,IEC60695-11-3,IEC60695-11-20

                    UL94,IEC60695-11-4,IEC60695-11-10