                    0.1kpa low pressure high and low temperature test machine

                    Product Description:Name:0.1kpa low pressure high and low temperature test machineType:BND-PTD-1000S1,This equipment mainly consists of five basic parts: test box, temperature circulation system, low pressure vacuum system, and program control system. among them:1. The test box includes the pressure vessel, the door, the insulation layer, the shell seal, the test signal lead-out hole and the external flange, and the indoor lighting.
                    Description

                    Product Description:

                    Name:0.1kpa low pressure high and low temperature test machine

                    Type:BND-PTD-1000S


                    1,This equipment mainly consists of five basic parts: test box, temperature circulation system, low pressure vacuum system, and program control system. among them:

                    1. The test box includes the pressure vessel, the door, the insulation layer, the shell seal, the test signal lead-out hole and the external flange, and the indoor lighting.

                    2. The temperature cycle system includes a refrigeration system and a heating system. The refrigeration system includes the original German blog semi-hermetic compressor, Danish Danfoss expansion valve, DuPont Refrigerant, Taiwan Collier plate heat exchanger, US TEMPRITE oil separator, Danfoss Denmark or the same brand of solenoid valves. The heating system includes electric heaters, using domestic brands and mature technology and reliable materials.

                    3. Low pressure vacuum systems include imported brands of vacuum pumps, vacuum gauges, vacuum electromagnetic block valves, vacuum bleed valves, vacuum trim valves, oil traps, pipes and hoses, and standard connectors.

                    4. The control system uses Chinese and English interfaces, and the control system uses self-developed software. The control system selects the brand components and controls the low pressure system, temperature circulation system, refrigeration unit, valve opening process, and test data processing (acquisition, storage, download).


                    Sample limitation

                    This test equipment is prohibited:

                    Test and storage of inflammable, explosive and volatile materials

                    Test and storage of corrosive material samples

                    Testing or storage of biological samples

                    Test and storage of strong electromagnetic emitter samples

                    volume

                    Inner size

                    Outer size


                    1000 L

                    W1000×H1000×D1000 mm

                    About W1600×H1800×D3200 mm (Subject to final design drawings)

                    1.1. Performance indicators

                    1.2. Test environment conditions

                    Environment temperature:5~35℃、relative Humidity ≤85%RH


                    The equipment shall not be used for testing or storage of articles containing inflammable, explosive or volatile or corrosive gases

                    1.3. Test methods

                    GB/T31467-2015

                    GB/T31485-2015

                    1.4. Temperature range

                    -70℃~+180℃

                    1.5. Temperature fluctuation

                    1.6. Temperature deviation

                    ≤  ±0.5℃(normal atmosphere,no-load)


                    ≤  ±2.0℃(normal atmosphere,no-load)

                    1.7. temperature gradient

                    4.0℃

                    1.8. vacuum range

                    Normal atmosphere-0.1KPa

                    1.9. vacuum accuracy

                    ±3%

                    1.10. vacuum testing time

                    18min

                    1.11. Heat load

                    400W at -54℃

                    Heat rate

                    (normal atmosphere

                    ,no-load)

                    -70℃-+100℃ average:3.5℃/min(normal atmosphere,no-load)

                    Cooling rate

                    (normal atmosphere

                    ,no-load)

                    +100℃--70℃ average :2.5℃/min(normal atmosphere,no-load)

                    1.12. Pressure range


                    0.1KPa~101.3 KPa

                    Setting range

                    Simulate altitude

                    1.09 kPa

                    30500 m

                    2.75 kPa

                    24400 m

                    4.43 kPa

                    21350 m

                    11.68 kPa

                    15250 m

                    19.16 kPa

                    12200 m

                    30.06 kPa

                    9150 m

                    46.54 kPa

                    6100 m

                    57.3  kPa

                    4550 m

                    69.66 kPa

                    3050 m

                    1.13. standards

                    GB/T2423.1-2008 Test A: Low temperature test method

                    GB/T2423.2-2008 Test B: High Temperature Test Method

                    GB/T2423.21-2008 Test M: Low Pressure Test Method

                    GB/T2423.25-2008 Test Z/AM: Comprehensive test of low temperature/low pressure

                    GB/T2423.26-1992 Test Z/BM: Comprehensive test of high temperature/low pressure

                    GJB150.3-1986 high temperature test

                    GJB150.4-1986 Low temperature test

                    GJB150.6-1986 Temperature altitude test

                    GJB360A-1996 Method 105: Low Pressure Test